1.
Microbiol Spectr ; 10(3): e0270921, 2022 06 29.
Article in English | MEDLINE | ID: covidwho-1846343

ABSTRACT

The study aimed to establish the performance of the SARS-CoV-2 Rapid Antibody Test (IgG and IgM) and the Elecsys Anti-SARS-CoV-2 S assay in vaccinated individuals. A panel of serum samples from Boca Biolistics was utilized to assess antibodies following vaccination, consisting of samples drawn prior to vaccination, after the first dose, or at least 14 days after the second dose of Moderna mRNA-1273 or Pfizer-BioNTech BNT162b2 COVID-19 vaccines. Agreement between the two methods was measured and stratified by test evaluator and assay lot. Agreement between the SARS-CoV-2 Rapid Antibody Test (IgG) and Elecsys Anti-SARS-CoV-2 S assay qualitative measurements at the different assessment points for both mRNA-1273 and BNT162b2 ranged between 97.06% (95% confidence interval [CI] 84.67, 99.93) to 100% (95% CI 82.35, 100). Agreement of the SARS-CoV-2 Rapid Antibody Test (IgG) with the Elecsys Anti-SARS-CoV-2 S assay was not highly influenced by either lot or evaluator. There was a medium-to-strong correlation between the semiquantitative SARS-CoV-2 Rapid Antibody Test (IgG) result and quantitative Elecsys Anti-SARS-CoV-2 S assay in samples taken after both doses of the vaccines, with higher intensity bands being associated with higher total anti-S antibody titer (mRNA-1273, P = 0.0019; BNT162b2, P < 0.0001). Conclusion Semiquantitative SARS-CoV-2 Rapid Antibody Test (IgG) and quantitative Elecsys Anti-SARS-CoV-2 S assay correlated well, suggesting that the SARS-CoV-2 Rapid Antibody Test (IgG) is helpful in understanding the immune response postvaccination. The current data support the use of the SARS-CoV-2 Rapid Antibody Test (IgG) in the vaccinated population. IMPORTANCE Serologic assays are an essential tool for seroprevalence surveys, for quality control of vaccines, and to determine the response to vaccination. Although a correlate of immunity has not yet been established for COVID-19 vaccines, antibody titers after natural infection and vaccination have been associated with protection from symptomatic SARS-CoV-2 infection. Rapid point-of-care assays can be of use in this context with advantages over centralized testing, such as speed and ease of use. The point-of-care SARS-CoV-2 Rapid Antibody Test (IgG) compared favorably to the Elecsys Anti-SARS-CoV-2 S assay with agreement rates above 97.06%, after one or two doses of Moderna mRNA-1273 or Pfizer-BioNTech BNT162b2. Semiquantitative SARS-CoV-2 Rapid Antibody Test (IgG) and quantitative Elecsys Anti-SARS-CoV-2 S assay results correlated well, suggesting that SARS-CoV-2 Rapid Antibody Test (IgG) is helpful in understanding the immune response postvaccination. The current data support the use of the SARS-CoV-2 Rapid Antibody Test (IgG) in the vaccinated population.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , BNT162 Vaccine , COVID-19/diagnosis , COVID-19/prevention & control , COVID-19 Vaccines , Humans , Immunoglobulin G , Seroepidemiologic Studies
2.
Int J Infect Dis ; 103: 636-641, 2021 Feb.
Article in English | MEDLINE | ID: covidwho-938978

ABSTRACT

OBJECTIVES: Due to the number of asymptomatic infections and limited access to high-performance antibody tests, the true prevalence and seropositivity of SARS-CoV-2 infection remains unknown. To fill this gap, the clinical performance of a point-of-care SARS-CoV-2 Rapid Antibody Assay, a chromatographic immunoassay for detecting IgM/IgG antibodies, in near patient settings was assessed. METHODS: Forty-two anti-SARS-Cov-2 positive (CoV+) and 92 anti-SARS-Cov-2 negative (CoV-) leftover samples from before December 2019 were assessed; the Elecsys® Anti-SARS-CoV-2 was used as the reference assay. Analytical specificity was tested using leftover samples collected before December 2019 from patients with common cold symptoms. RESULTS: The SARS-CoV-2 Rapid Antibody Test was 100.0% (95% CI 91.59-100.0) sensitive and 96.74% (95% CI 90.77-99.32) specific, with 0.00% assay failure rate. No cross-reactivity was observed against the common cold panel. Method comparison was additionally conducted by two external laboratories, using 100 CoV+ and 275 CoV- samples, also comparing whole blood versus plasma matrix. The comparison demonstrated 96.00% positive and 96.36% negative percent agreement for plasma with the Elecsys Anti-SARS-CoV-2 and 99.20% percent overall agreement between whole blood and EDTA plasma. CONCLUSION: The SARS-CoV-2 Rapid Antibody Test demonstrated similar performance to the manufacturer's data and a centralised automated immunoassay, with no cross-reactivity with common cold panels.


Subject(s)
Antibodies, Viral/blood , COVID-19/diagnosis , SARS-CoV-2/immunology , COVID-19 Testing , Cross Reactions , Humans , Immunoassay/methods , Point-of-Care Systems